DVL 2000/SP6 | DVL | Insulation Digital Technology

DVL 2000/SP6 | DVL | Insulation Digital Technology Skip to main content EN JP CN EN JP CN Check Stock Career Investors Contact Products Applications Support About Lem Search Current Sensors 45-90 A 90-180 A 187.5-375 A 375-750 A 750-1500 A 1500-3000 A 3000-6000 A 6000-12000 A 12000-24000 A Other value All Current Sensors Voltage Sensors 25-50 V 50-100 V 100-200 V 200-400 V 400-800 V 800-1600 V 1600-3200 V 3200-6400 V All Voltage Sensors Integrated Current Sensors GO Series HMSR Series GXS Series GXN Series GXM Series All Integrated Current Sensors Rogowski Coil ART Series ARU Series ARH Series INTEGRATORS FOR ROGOWSKI COILS Energy Meters DCES DCBM 400 & 600 DCBM 100 TEMA4G EM4T II All Energy Meters Automotive Battery Management EV Chargers Automotive Motor Control Smart Grid Welding Automation Drives High Precision Power Supplies Renewable Energies Trackside Traction After Sales & RMA Merchandize authorization RMA Categories All after sales and RMA Downloads Application Notes Brochures Certificates All Downloads Technical FAQs General All Technical FAQs Company Information History Board of Directors & Committees Organization Values Compliance Sustainability Our locations All Company Information Quality & Environment Quality Environment All Quality & Environment Our partners Become a LEM Supplier Our general terms & conditions Our distributors News & Events All News & Events What do you need ? Product information Check Stock Global information GO EN JP CN EN JP CN Products Current Sensors Voltage Sensors Integrated Current Sensors Rogowski Coil Energy Meters Applications Automotive Battery Management EV Chargers Automotive Motor Control Smart Grid Welding Automation Drives High Precision Power Supplies Renewable Energies Trackside Traction Support After sales and RMA Downloads Technical FAQs About Lem Company Information Quality & Environment Suppliers News & Events Check Stock Career Investors Contact What do you need ? Product information Check Stock Global information GO Home Product List lem_current_page : DVL 2000/SP6 DVL

Voltage transducers for Industrial and Traction - for small and medium voltage measurements from 50 to 2000 VRMS with an unique compact design (30% lighter, 30% power saving) and excellent overall accuracy. 100 % compatible with previous generations of transducers in performance and footprint (LV100).

DVL 2000/SP5 DVL 2000/SP9 Model details DVL 2000/SP6

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

Series DVL Measurement Voltage Nominal Value 2000 V Measuring Range 3000 V Second. Nominal Signal Current Second. Nominal Signal Value Instantaneous 50 mA Primary Signal AC + DC Supply Voltage External DC Bipolar Supply Voltage Range 15 - 24 V Accuracy 0.5 % Op. Temperature -40 °C / 85 °C Technology Insulation Digital Technology Mounting Panel Applications Traction PICTURE FRONT BACK LEFT RIGHT Download Relative information Download 3D Download Datasheet Order from our distributors Check Stock $(el).parents('.row.hide').removeClass('hide')" disable-search-js="true" country-js="drupalSettings.lem.octopart_country || 'US'" token-js="drupalSettings.lem.octopart_token"> Series Product of the same series DVL 1000

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 1000-UI

Unipolar and insulated DC measurement up to 1000 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1000/SP1

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

DVL 1000/SP5

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with shorter M5 threaded studs and,output connections on M5 threaded inserts.

DVL 1000/SP7

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input and output connections on cables

DVL 1000/SP8

Bipolar and insulated measurement up to 1000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

DVL 1000/SP9

Bipolar and insulated measurement up to 1000 V, 6.66 V Voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.

DVL 125

Bipolar and insulated measurement up to 125 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 150

Bipolar and insulated measurement up to 150 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 150-UI

Unipolar and insulated DC measurement up to 150 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1500

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 1500-UI

Unipolar and insulated DC measurement up to 1500 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 1500/SP1

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

DVL 1500/SP5

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input and output connections on cables.

DVL 1500/SP6

Bipolar and insulated measurement up to 1500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on cable.

DVL 1500/SP7

Bipolar and insulated measurement up to 1500 V, 7.5 V voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.

DVL 150/SP1

Bipolar and insulated measurement up to 150 V, 50 mA current output, Input and output connections with M5 threaded studs.

DVL 2000

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 2000/SP1

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on Burndy connector.

DVL 2000/SP5

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input and output connections on cables.

DVL 2000/SP9

Bipolar and insulated measurement up to 2000 V, 50 mA current output, Input and output connections with M5 threaded studs.

DVL 250

Bipolar and insulated measurement up to 250 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 250-UI

Unipolar and insulated DC measurement up to 250 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 50

Bipolar and insulated measurement up to 50 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 50-UI

Unipolar and insulated DC measurement up to 50 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 500

Bipolar and insulated measurement up to 500 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 500-UI

Unipolar and insulated DC measurement up to 500 V, 4-20 mA current output @ +Vpn (4 mA @ 0A, 3 mA @ -Vpn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 750

Bipolar and insulated measurement up to 750 V, 50 mA current output, Input connections with M5 threaded studs and,output connections with M5 threaded studs + fastons.

DVL 750-UI

Unipolar and insulated DC measurement up to 750 V, 4-20 mA current output @ Ipn (4 mA @ 0A, 3 mA @ -Ipn), Input connections with M5 threaded studs and,output connections on M5 threaded studs + fastons.

DVL 750/SP3

Bipolar and insulated measurement up to 750 V, 62.5 mA current output, Input connections with M5 threaded studs and,output connections on Burndy connector.

DVL 750/SP4

Bipolar and insulated measurement up to 750 V, 50 mA current output, Input connections with M5 threaded studs and,output connections on burndy connector

DVL 750/SP5

Bipolar and insulated measurement up to 750 V, 7.5 V voltage output, Input connections with M5 threaded studs and,output connections on M5 threaded inserts.

Order Contact Information Contact us Security & Privacy Portal Terms of sales Terms of use Contact   Headquarters LEM International SA
Route du Nant-d’Avril, 152
1217 Meyrin
Switzerland Tel. : +41 22 706 11 11
Fax : +41 22 794 94 78